- Home
- Products
- SICK
- Registration Sensors
- Contrast Sensors
- KTL180-ME/MF/ML/MM Contrast sensors SICK | Sensorik Automation SB
KTL180-ME/MF/ML/MM Contrast sensors SICK | Sensorik Automation SB
Quantity
Download Files
KTL180-MM4P41ZZZZZ.pdf (657.92 KB)
KTL180-ML4P41ZZZZZ.pdf (657.88 KB)
KTL180-MF2P41ZZZZZ.pdf (671.11 KB)
KTL180-ME2P41ZZZZZ.pdf (670.78 KB)
KTL180-MM4P41ZZZZZ.pdf (657.92 KB)
KTL180-ML4P41ZZZZZ.pdf (657.88 KB)
KTL180-MF2P41ZZZZZ.pdf (671.11 KB)
KTL180-ME2P41ZZZZZ.pdf (670.78 KB)
Contrast sensors |
KTL180
- Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
- Light source: LED, White
- Sensing distance: 1,400 mm
- Switching output: NPN
- Connection type Detail: Male connector M8, 4-pin
- Device type: Expansion unit
-
Features
Special applications - Device type Expansion unit Indication Display Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm Sensing range 0 mm ... 1,400 mm, Proximity system 1) Sensing distance 1 mm, 1,400 mm 1) Housing design (light emission) Rectangular Light source LED, White 2) Angle of dispersion Approx. 65° 3) Wave length 400 nm ... 750 nm Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic Delay time Adjustable Special features Multi-function input, no L+/M, expansion unit for BUS mode Delivery status Teach-in dynamic Parameter presettings None - 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) See LL3 fiber-optic data.
-
Technical drawings
Contrast sensors |
KTL180
- Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
- Light source: LED, White
- Sensing distance: 1,400 mm
- Switching output: PNP
- Connection type Detail: Male connector M8, 4-pin
- Device type: Expansion unit
-
Features
Special applications - Device type Expansion unit Indication Display Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm Sensing range 0 mm ... 1,400 mm, Proximity system 1) Sensing distance 1 mm, 1,400 mm 1) Housing design (light emission) Rectangular Light source LED, White 2) Angle of dispersion Approx. 65° 3) Wave length 400 nm ... 750 nm Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic Delay time Adjustable Special features Multi-function input, no L+/M, expansion unit for BUS mode Delivery status Teach-in dynamic Parameter presettings None - 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) See LL3 fiber-optic data.
-
Technical drawings
Contrast sensors |
KTL180
- Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
- Light source: LED, White
- Sensing distance: 1,400 mm
- Switching output: NPN
- Connection type Detail: Male connector M8, 4-pin
- Device type: Base unit
-
Features
Special applications - Device type Base unit Indication Display Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm Sensing range 0 mm ... 1,400 mm, Proximity system 1) Sensing distance 1 mm, 1,400 mm 1) Housing design (light emission) Rectangular Light source LED, White 2) Angle of dispersion Approx. 65° 3) Wave length 400 nm ... 750 nm Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic Delay time Adjustable Special features Multi-function input, base unit for BUS mode Delivery status Teach-in dynamic Parameter presettings None - 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) See LL3 fiber-optic data.
-
Technical drawings
Contrast sensors |
KTL180
- Teach-in mode: 1-point teach-in, 2-point teach-in, teach-in dynamic
- Light source: LED, White
- Sensing distance: 1,400 mm
- Switching output: PNP
- Connection type Detail: Male connector M8, 4-pin
- Device type: Base unit
-
Features
Special applications - Device type Base unit Indication Display Display LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual value (red indicator) are displayed simultaneously, display of parameters Dimensions (W x H x D) 10.5 mm x 33.2 mm x 71.9 mm Sensing range 0 mm ... 1,400 mm, Proximity system 1) Sensing distance 1 mm, 1,400 mm 1) Housing design (light emission) Rectangular Light source LED, White 2) Angle of dispersion Approx. 65° 3) Wave length 400 nm ... 750 nm Teach-in mode 1-point teach-in, 2-point teach-in, teach-in dynamic Delay time Adjustable Special features Multi-function input, base unit for BUS mode Delivery status Teach-in dynamic Parameter presettings None - 1) Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range depends on fiber-optic cable.
- 2) Average service life: 100,000 h at TU = +25 °C.
- 3) See LL3 fiber-optic data.
-
Technical drawings